Handcrafted Pro Audio HPA-DI1 Passive DI — Jensen JT-DB-EPC Transformer

$199.00

A hand-built passive direct box with a Jensen JT-DB-EPC transformer at its heart, wired to Jensen’s own reference circuit. Flat from 20 Hz to 20 kHz within ±0.25 dB, with 100 dB of common-mode rejection at 60 Hz, and it takes up to +34.5 dBu with the −15 dB pad engaged. It has genuine Neutrik connectors, latching E-Switch pushbuttons, and a ground lift that actually lifts. No power required. Hand-built in Virginia.

2 in stock

SKU: HPA-DI1 Category:

Description

Studio-quality sound, by the numbers

A passive DI is a transformer in a box, so the transformer decides almost everything:

  • how much hum gets through
  • how hard you can hit it before the low end distorts
  • whether the top end survives a long XLR run

This DI is built around the Jensen JT-DB-EPC, a transformer designed specifically for direct boxes. It’s the same transformer Radial builds its JDI around.

It’s wired to the circuit Jensen uses to specify that transformer: a 6.81 kΩ feed resistor, the transformer, and a 1 kΩ preamp load. So Jensen’s published figures are this box’s figures, not estimates:

  • 20 Hz – 20 kHz, ±0.25 dB
  • Under 0.001% distortion at 1 kHz, +4 dBu
  • 100 dB common-mode rejection at 60 Hz
  • A 150 Ω balanced output that drives a long XLR run without hum or high-frequency loss

The transformer

The JT-DB-EPC is an 11.52:1 step-down transformer with dual Faraday shields, housed in a 30 dB magnetic shield can:

  • The Faraday shields are grounded screens between the windings. They stop noise on the cable’s ground and shield from coupling across from one winding to the other, which is where the 100 dB of common-mode rejection comes from.
  • The magnetic can keeps stray hum fields from power supplies and lighting out of the core.

The signal crosses through the transformer, so there’s no direct signal connection between your instrument and the console. With GND LIFT pressed, there’s no ground connection either.

The −15 dB pad, and why it matters

Keyboards, synths, active basses, laptops and playback devices put out line level, which is many times hotter than a passive guitar pickup. Even after the DI steps the signal down, a hot line source can overdrive a console’s mic preamp with the gain turned all the way down. A transformer also has the least headroom at low frequencies, where those sources carry the most energy.

The PAD is a 15 dB attenuator that sits ahead of the transformer:

  • The console gets a level it can handle.
  • The most you can feed the jack rises from +19.5 dBu to +34.5 dBu at 20 Hz.
  • It only affects the XLR output. The THRU jack to your amp is never attenuated, so the player hears no change on stage.

A ground lift that works properly

Stage hum is usually a ground loop: the amp and the console are both earthed, and current flows in the cable shield between them. Press GND LIFT to break that loop at the DI. Two design details make sure it really does:

  • Plastic-nose Neutrik jacks. A metal-nose jack ties the cable’s ground to the metal case the moment a plug goes in, which bridges straight across a ground lift. These jacks have no chassis contact, so when the lift is pressed the ground is genuinely lifted.
  • An RF bridge. A 51 Ω resistor and 10 nF capacitor stay across the lift, so radio-frequency interference still has a path to the chassis while the audio ground is broken.

Every unit’s lift is checked with a meter before it ships.

Neutrik connectors, E-Switch switches, no wiring

  • Neutrik NC3MD-H XLR male output, and two Neutrik NRJ6HF fully threaded 1/4″ jacks for INPUT and THRU, wired in parallel.
  • E-Switch latching DPDT pushbuttons for PAD and GND LIFT.
  • Every connector and both switches are soldered to one circuit board, and the enclosure holes locate them. There’s no internal wiring to fatigue or work loose.
  • A star-grounded board, so ground-loop current never shares copper with your signal.

Completely passive

There’s nothing to power: no battery to die halfway through a set and no phantom power needed. Phantom power on the channel does no harm, so leave it on or off.

Good to know

  • Loading on passive pickups. Like every passive DI, this one loads a passive guitar or bass pickup at about 148 kΩ, compared with an amp’s 1 MΩ. That softens the pickup’s treble peak a little, which is part of why a DI’d instrument sounds different from a miked amp. INPUT and THRU are in parallel, so your amp sees the same load. If you want the full top end, put a buffer pedal ahead of the DI.
  • Piezo pickups without a preamp need a much higher input impedance than any passive DI provides. Use an active DI or a preamp for those.

Hand-built in Virginia

Each unit is assembled, soldered and tested by hand by Ryan at Handcrafted Pro Audio VA, who has more than 25 years in professional audio: cable fabrication, live sound and broadcast AV. These aren’t assembled from a kit.

Every unit is tested before it ships with a real instrument, usually a bass, plugged into the 1/4″ input. The signal is checked at the XLR output and at the THRU jack, the pad is checked to cut the level as it should, and the ground lift is checked with a meter to confirm it fully disconnects the input ground from the chassis.

What’s in the box

  • Handcrafted Pro Audio Passive DI
  • Printed user guide

Warranty: 1-year warranty against defects in parts and workmanship, from the date of purchase. It doesn’t cover the finish (scratches, scuffs and other cosmetic wear) or damage from abuse or misuse.

Specifications

Model HPA-DI1 (Handcrafted Pro Audio Passive DI)
Type Passive, transformer-isolated, 1 channel
Transformer Jensen JT-DB-EPC, 11.52:1, dual Faraday shields, 30 dB magnetic shield can
Frequency response 20 Hz – 20 kHz, ±0.25 dB
Distortion (THD) < 0.001% at 1 kHz, +4 dBu · 0.036% at 20 Hz, +4 dBu
Common-mode rejection 100 dB at 60 Hz
Input impedance 148 kΩ (100 kΩ with pad)
Output impedance 150 Ω
Insertion loss −22 dB (−37 dB with pad)
Pad −15 dB, XLR output only
Maximum input +19.5 dBu at 20 Hz; +34.5 dBu with the pad in
Ground lift Yes, with 51 Ω + 10 nF RF bridge
Polarity Non-inverting, pin 2 hot
Connectors Neutrik NC3MD-H XLR male · 2 × Neutrik NRJ6HF 1/4″ TS/TRS (INPUT, THRU, parallel)
Switches E-Switch latching DPDT pushbuttons (PAD, GND LIFT)
Power None required; unaffected by phantom power
Enclosure 125B aluminum, powder-coated black, UV-printed labels
Dimensions 132 × 68 × 40.3 mm (5.20 × 2.68 × 1.59 in), L × W × H including connectors; body 123 mm (4.84 in) long
Weight 10.75 oz (305 g)

Performance figures are Jensen’s published typical values for the JT-DB-EPC in its datasheet test circuit, which is the circuit this DI is built on. Maximum input is the guaranteed minimum.

Additional information

Weight 0.67 lbs
Dimensions 5.20 × 2.68 × 1.59 in

Reviews

There are no reviews yet.

Be the first to review “Handcrafted Pro Audio HPA-DI1 Passive DI — Jensen JT-DB-EPC Transformer”

Your email address will not be published. Required fields are marked *